JUKI · verified physical machine

LU-1560N-7

View cited identity evidence · 2 unique proof passages

Jump to: Proof E3, Proof E4

Identity verified · evidence for each owner answer

What is actually verified

Cited machine label — physical identity not yet accepted

The official evidence supports the displayed name or model label. SewGraph has not yet accepted one exact physical-machine entity for this route, so no compatibility answer is attached.

A cited label is not proof that similarly named, regional, revised, or same-code machines are physically identical.

Identity verified · evidence for each answer

Using and maintaining this machine

Check the conditions alongside each answer. Foot attachment, shank type and adapter requirements are separate; one does not establish universal accessory fit.

Features and specifications

Maximum sewing speed

conditional

2,500sti/min

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer.

Source evidence · 1 unique proof passage: Profile Proof E1

Maximum stitch length

conditional

9mm

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer.

Source evidence · 1 unique proof passage: Profile Proof E1

Presser feet and adapters

Lift

conditional

Auto: 16mm

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer. Lift and movement do not establish foot mount or item fit.

Source evidence · 1 unique proof passage: Profile Proof E1

Alternating vertical movement

conditional

1~6.5mm

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer. Lift and movement do not establish foot mount or item fit.

Source evidence · 1 unique proof passage: Profile Proof E1

Needles and threading

Printed needle specification

conditional

135×17 (Nm160) Nm125~Nm180

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer. Preserve printed system, parenthetical notation and size range; no equivalent needle system, requirement, or substitute is inferred.

Source evidence · 1 unique proof passage: Profile Proof E1

Thread range

conditional

#30~#5, B46~B138, Nm=60/3~20/3

  • Only LU-1560N-7 in the cited left-lower table, first value column jointly headed LU-1560N-7 and LU-1561N-7; exclude third LU-1565N column on physical page 7; Standard gauge in page heading; five-way switch is an option, not standard equipment. Parenthetical Nm160 meaning is not inferred. Catalog maxima are not everyday operating recommendations. No adjacent model or suffix transfer. Thread ranges do not establish fabric or brand fit.

Source evidence · 1 unique proof passage: Profile Proof E1

Bobbins and hook

Sources for the owner answers above
Official OEM PDF

What this passage supports

  • Maximum sewing speed: 2,500sti/min
  • Maximum stitch length: 9mm
  • Lift: Auto: 16mm
  • Alternating vertical movement: 1~6.5mm
  • Printed needle specification: 135×17 (Nm160) Nm125~Nm180
  • Thread range: #30~#5, B46~B138, Nm=60/3~20/3
Model name: LU-1560N-7; Max. sewing speed: 2,500sti/min; Max. stitch length: 9mm; Presser foot: Auto: 16mm; Alternating vertical movement: 1~6.5mm; Needle: 135×17 (Nm160) Nm125~Nm180; Thread: #30~#5, B46~B138, Nm=60/3~20/3
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
Visually verified transcription of a scanned page
Visual verification
Checked 2026-09-28T16:21:43Z. The page image and transcription are hash-bound in the evidence record.
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
a03b2a22f46eaba5022b8673210467463b6fee2c0feec2ed7bd3301fca9b7bb1
Destination status
direct_pdf
Machine facets and OEM groups

Cited machine facets

Identity and compatibility badges

Identity families, physical traits, and OEM accessory groups stay separate. A group badge applies only to its named program and domains.

needle system135×17
Detailed specifications, compatible parts, and source library

Evidence coverage

Core answers and cited items

Machine category: Not yet established

Core domains answered: None yet

Domains with cited compatible items: None yet

Unknown is not incompatible. A missing answer means the current official evidence does not support one yet.

Specifications

Documented machine facts

Multiple cited representations for one field share one row. SewGraph preserves every value and exact proof passage; it does not guess which representation is “raw” or “normalized” when the public projection does not label that distinction.

needle

needle system135×17

View exact evidence · 1 unique proof passage: Proof E5

Official source library

Documents used on this page

Open the exact OEM PDF page or captured HTML edition when a safe destination exists; otherwise SewGraph labels the OEM support-page fallback honestly.

JUKI 2026 non-apparel general catalog

machine catalog

Open official source destination · 1 unique proof passage: Proof E1

Evidence library

5 exact proof passages from 1 OEM document

Every passage below says exactly what visible fact it proves. Repeated references to the same locator are counted once; identity evidence never counts as compatibility evidence.

Compatibility proof passages: 0. The passages below support identity facts only.

Open exact proof passages · 5 unique proof passages
Official OEM PDF

What this passage proves

  • Identity — preferred display name: LU-1560N-7
LU-1560N-7
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
native
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
890eae6e986c5444d3093be57801d8573ec91d3f1d6ceb977b086630a6f17f2d
Destination status
direct_pdf
Official OEM PDF

What this passage proves

  • Identity — model code: LU-1560N-7
LU-1560N-7
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
native
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
70899a11b4f0faeffc29c2f5d355da1a21753b6147f17a74dda97af76c71f3f5
Destination status
direct_pdf
Official OEM PDF

What this passage proves

  • Identity — printed machine name: LU-1560N-7
(Standard gauge) LU-1560N-7 (Standard gauge) LU-1560N (Gauge for Europe) LU-1561N-7 (Gauge for Europe) LU-1561N (With organized split needle bar) LU-1565N The two-needle machine
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
native
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
ff8dd3512f282d08633a179b5523361bfcdef1940dc15add21a5ccfe54566ff1
Destination status
direct_pdf
Official OEM PDF

What this passage proves

  • Identity — printed machine name: LU-1560N-7
LU-1560N-7
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
native
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
ccfdfad7ab0069e790d01e6f3352d0ebff69aa501f64cd10ac81726bbc621a56
Destination status
direct_pdf
Official OEM PDF

What this passage proves

  • needle fact — needle system: 135×17
LU-1560N-7
Document
JUKI 2026 non-apparel general catalog
Issuer
JUKI
Extraction
native
PDF page
7
Open source
Advanced technical receipt
Asset SHA-256
adcd36071ddf8a75929bd7e00d285157bd25ddeecfefb6a7c6825e2b24a47c28
Locator
962635e67047af1ba6ed48842a9c1a71340d6e89caee6b754b744a6fcde50d62
Destination status
direct_pdf

What is supported, and what remains open?

0 supported answers and 6 answers with conditions or remaining limits. Evidence coverage is not a probability of accuracy.

Unresolved owner questions (2)
  • Mount or fit: Not established — Not yet verified: This table does not establish mount, shank, adapter, or compatible feet.
  • Class or fit: Not established — Not yet verified: No bobbin class, case, part or interchangeability is established.

Report a correction or share an OEM source

Advanced provenance and dataset receipt

Public snapshot a1cc1aceef228fcf33329e37165ab888ce5b9fe3f13eb56967ae0fbf41d8d8a7

Catalog e156281c7d3048027b5ac89e7476be8f54dd5a9309505e96260b0455d3cd2a7e · exact native quotes only · dossier method sewgraph-model-dossier-v2